Home > Buy Now > Tanker > Cargo Tank Monitoring system with Local and Remote Display/CMS-MIA-H, SPT-3500
 


Hanla Level Co,. Ltd.
 
icon Cargo tank level, Alarm and pressure monitoring system
icon Level Gauges
icon Level Switches
icon Tank Level Monitoring System

line

icon Company Profile
icon Selling Leads
icon Index
icon Bulletin Board
icon Guest Book

line



visitors: 23628
 
Contact us
Hanla Level Co,. Ltd.
[Korea]
Address:
1610-5 Songjeong-dong, Gangseo-gu, Busan 618-270 Korea
Phone:
82-51-6013000
Contact name:
Robert, Jung , Assistant manager
Inquire now









Hanla Level Co,. Ltd.
 
Cargo tank level, Alarm and pressure monitoring system

Cargo Tank Monitoring system with Local and Remote Display/CMS-MIA-H, SPT-3500

Inquire now

Cargo Tank Monitoring system with Local and Remote Display/CMS-MIA-H, SPT-3500

Click to enlarge image

 Model Number HANLA-Tokyo Keiso

■ General

The SPT-3500 LIQUID LEVEL is the newest version of magnetic float level gauge for marine tankers which has been developed based on the long time field experience.
The detection of float position is conducted by HALL IC elements to eliminate problem of contact fusing and/or accuracy failure caused by existing reed switch system.
By this remarkable sensing system, long time stability and maintenance free operation have been achieved.
The measurement is free from the conductivity and/or dielectric constant of the cargo liquids.
Thus SPT-3500 is widely suitable for measurement and control or cargo liquid levels at crude oil carriers, coaster tankers, product carriers chemical carrier, etc.
LEVEL ALARM SYSTEM is perfectly separated from level and temperature monitoring system electrically, and the independent level alarm sensor is separated from level and temp. sensor too.
When the liquid level reaches a set point, the reed switch is actuated by magnetic float. This signal is connected to annunciator card through safety barrier. At the same time, we can get audible and visible alarm on the main control panel as well as external alarm on the bridge top.
The 95% of volume is normally for high alarm, and 98% of volume is normally for overfill alarm.

■ System Construction

System/Model
Description
Level Sensor
Safty Barrier
Main Control Panel
Cargo Monitoring System/
CMS-MIA-H SPT-3500
Intrinsically safe
Level and temp.
Monitoring
System
Local Gauge
SPT-3500S-3R
TZB-101
Multi-Monitor
DIR-M1600 II
Independent leve
Alarm system
- High level alarm
- Overfill alarm
Level Switch
TMR-701T
TMR-702T
KFD2-SR2-Ex2.W
Alarm Module
8510

■ Features

  • Compact and cost saving design.
  • HALL IC Elements, pure electric position detection:
    -Grade up from existing reed switch system.
    -Highly reliable and stable for long time operation.
    -Highly precision for operation.
  • 3 Point of temp. measurement and transmission.
  • 16 Bit CPU Data processing:
    -Intelligent signal processing unit with 16 bit micro processor achieves high reliability and high function such as self-diagnosis and setting of measuring liquid density.
  • Separatable LCD indicator.
    -LCD indicator may be separated from the sensor.
  • 2 Core cable data transmission and easy wiring:
    -Liquid level and maximum 3point temp. data are sent to CCR by serial BCD signal through 2 core cable only including power supply to the deck.
  • Full line up of CCR indication system:
    -Full line up from individual indicator to computer based system is ready to meet for requirements.

■ Application

This system is used for monitoring for level, alarm and temperature of the liquid in cargo tanks.

■ Technical specification for system

Detection unit
Alarm - by magnetic float and reed switch type.
Level - by magnetic float and HALL IC element.
Temp. - by PT-1000RTD.
Accuracy
Alarm - ±5m/m on level rise or fall
Level - every 10mm(standart), every 5mm(option)
Temp. - ±1.0°C
Measuring range
Alarm -95%, 98% of volume
Level - Max. 40m
Temp. - -25~150°C
Construction
Alarm - IP56 over and intrinsically safety EEx ia II C T6
Level and temp. - IP56 over and intrinsically safety EEx ia II C T4
Indication
By selector type LCD 6digit indication
1) Level - 5m/m unit(0~39999m/m)
2) Temp. (U : upper)°C or °F unit, (M : middle)°C or °F unit, (L : lower)°C or °F unit
Output
Digital serial code pulse (2wire system including power supply, exclusive receiving unit is required)
External alarm
High and overfill alarm on the bridge top.
Power source
AC 110/220V, 60HZ/Back up source : DC24V
Specific gravity
Min. 0.65~1.5
Installation
JIS 5K 150A FF, 5K 200A FF
Conduit connection
JIS 5K 32A
Amb. temperature
-25~75°C
Material
Housing -SUS304, Float/Guide pipe - SUS316
Indicator housing : SUS304

■ Specification

  • Indication - Individual tank LED indicator
  • Tank selector and temp. element selector key are provided.
  • Level : 0~39999m/m(ullage or sounding selectable)
  • Level status : 2 digital
  • Alarm setting and monitoring :
    1) 4 level alarms(HH, H, L, LL)for 16tanks.
    2) 2 temp. alarms(H, L)for each element of tanks(TU, TM, TL)
    2points x 3elements x 16tanks=96points
  • Output : RS-232C port for indicator RS-232C port for loading computer 4 points of alarm contact for :
    a) common for all temp. alarms
    b) common for all level alarms

■ Cargo Monitoring Panel

The cargo monitoring panel will be designed and arranged for level alarm, high temp. alarm, and temp./level measurement based on the number of tanks and tank lovation etc.

The cargo tank monitoring panel gives audible and visible alarm as well as carto tank level, temp. Indication on the minic board, and also external alarm for high and high-high level shall be provided by cargo monitoring panel.




Inquire now


   
 
 

Related products from premium suppliers on EC21