Click to enlarge image

 Model Number Vapour pressure and oxygen sampling

■ General

Vapour emission control system is intended for analyzing the waste vapour gas for oxygen gas content.
The system also includes the pressure transmitter which can monitor the pressure on the waste vapour line.
The system consists of two cabinets; a detector cabinet in which the pressure transmitter, oxygen sensor, flow alarm sensor, sample selector valve and purge valve are included, and the monitoring & alarm panel on which the alarm unit, oxygen indicator are provided.
The detector manifolds and the monitoring & alarm panel is mounted in the cargo control room.

■ Principle of operation

The sample tubes in the detector cabinet run from the sample point inlets to oxygen sampling selector valve and mode selector valve. Exiting from this single tube is leading the chosen sample gas through filter between oxygen sampling selector valve and mode selector valve, and then finally passes the oxygen sensor, exhausted through the exhausting line on the cabinet panel.
The display shows the O2 concentration from 0.0 to 25.0V% O2 on the oxygen monitor and the "High oxygen content alarm" is activated at 8V% O2.
The " Flow failure" is also operated when the flow is stopped.
The display shows the pressure transmitted from waste vapour line on the vapour pressure indicator from 0 to 200 mbar.
The "Low pressure alarm" is also activated at 10 mbar and the "High pressure alarm" ; at 120mbar.
It is possible to increase or decrease the pressure alarm value freely and the external alarm output relay for all alarm can be provided as optional items.

■ Features

  • Intrinsically safe detecting is applicable to all of inflammable fluids
  • All stainless steel material pressure sensor
  • Individual adjustable alarm for oxygen and pressure
  • Most advanced electronic technology for high reliability and durability.

■ Technical Specification

System

  • Main power supply : AC 110/220V, 50~60Hz
  • System power : DC 24V
  • Air supply : 4~7bar
  • Function :
    - Inert gas pressure display(0~200mbar)
    - Inert gas high pressure alarm(120mbar)
    - Inert gas low pressure alarm(10mbar)
    - Oxygen content display(0~25% V% O2)
    - Oxygen content high alarm(8 V% O2)
    - Flow failurealarm(If the flow is stopped)
    - External alarm(option)
  • Enclosure : EEx ia II C T4

Pressure transmitter

  • Range : 0~200mbar
  • Power supply : 17~28vdc
  • Output : 4.......20mA
  • Safety : EEx ia II C T4
  • Accuracy : ±0.2% of F.S

Digital indicator

  • Size : 48H x 96W x 112D
  • Input : 4......20mA
  • Output contact : H and L alarm

Oxygen sensor

  • Range : 0~25% O2
  • Power supply : DC 24V
  • Output : 4........20mA
  • Safety : EEx ia II C T4
  • Accuracy : ±2% of F.S

Alarm Annunciator

  • 10 channel type
  • Power supply : DC 24V
  • Function : Accept horn, Accept flash, Test function